We all know that the transformer is a static device that transfers energy from one part to another part without changing power and frequency. Now, let’s see in the transformer why the low voltage winding is placed on the limb, and why not high voltage winding.

There are two reasons because of those reasons the low voltage winding is placed on the limb, such as:

01. To reduce insulation cost

02. To reduce the size of the transformer

Both the coil of cylindrical type are placed on both the limbs(the vertical portion of the core is called the limb), the low voltage coil is placed near the core whereas the high voltage coil is placed above the low voltage coil to reduce insulation cost and size of the transformer. Now I will explain how it will reduce costs.

Let’s consider two cases:

Case 01: Low voltage winding is placed on the limb

Case 02: High voltage winding is placed on the limb

Case 01:  Low voltage winding is placed on the limb and of a transformer of 110KV/33KV.

Low Voltage Winding Is Placed On Core Instead Of HV Winding

We will analyze how much insulation is required.

Total insulation required to withstand voltage is = Insulation required to withstand voltage near core + Insulation required to isolate high and low voltage winding.

= 33 KV + (100 – 33)KV

= 33 KV + 77 KV

= 110 KV

Therefore, if the low voltage winding is placed on a limb first, then the insulation required is to withstand 110 kV voltage.

Case 02: High voltage winding near to limb and the transformer is of 110 kV/ 33 kV.

Total insulation required to withstand voltage is = Insulation required to withstand voltage near core + Insulation required to isolate high and low voltage winding.

= 110 KV + (110 – 33) KV

= 110 KV + 77 KV

= 187 KV

Therefore, if high voltage winding is placed on a limb, then the insulation required is to withstand 187 kV voltage.

If the insulation required is more then the size of the transformer also increases. If the insulation required is less then the size of the transformer is also reduced, this is true in case 01. If we use more insulation then the cost will also increase.

Well, guys, that’s why the low voltage winding is placed on the limb and the high voltage winding is placed above the low voltage winding.

I hope this article may help you all a lot. Thank you for reading.