  • 1. Best conductor silver > copper > gold > aluminium
  • 2. The best insulator is Diamond.
  • 3. Carbon is a semiconductor.
  • 4. Copper is not present in sufficient quantity on earth so aluminum is used as a conductor.
  • 5. Galium arsenide for Red light from the LED
  • 6. Galium phosphide for Greenlight from the LED
  • 7. In the seven-segment display, 7 LED’s are used
  • 8. Photo-coupler = LED + Photo Diode
  • 9. Diode = uncontrolled rectifier
  • 10. SCR= controlled rectifier
  • 11. In Scr, the gate is controlled element
  • 12. SCR is 4 layer, 3 junctions, 3 terminal device
  • 13. A diode is 2 layer, 1 junction, 2 terminal device
  • 14. P-type semiconductor = trivalent impurity.
  • 15. N-type semiconductor = pants valent impurity
  • 16. Transistor use as an amplifier…
  • 17. In the transistor, the collector has the largest size and base has the smallest size
  • 18. In a transistor, the emitter has maximum dopping and base has minimum dopping
  • 19. Common emitter connection is suitable for amplifier

Important On electrical engineering interview question and answer

  • 1. Dc is more dangerous from AC
  • 2. Frequency of Dc is Zero
  • 3. String Efficiency on dc is 100%
  • 4. Due to skin effect, AC resistance is 1.5 time from dc resistance
  • 5. Skin effect visible on only AC supply
  • 6. Non-uniform distribution of electrons or current in a conductor is called skin effect .. Maximum current at the surface of conductor and minimum at the center
  • 7. For AC calculation RMS values are used
  • 8. For dc calculation all values are used
  • 9. For square wave RMS value = Avg value = maximum value
  • 10. 50Hz frequency used from the point of view of flicker
  • 11. At high frequency, (above 50hz) losses increase 
  • 12. At low frequency ( below 50hz) flicker occurs

Basic Electrical Answers

  • 1. Fuse material (lead 37%+ and tin 63%)
  • 2. Soldering material ( lead 60% + tin40%)
  • 3. Fuse wire= high specific resistance and low melting point
  • 4. Switch and fuse always connect in phase
  • 5. Neutral is used as a return conductor
  • 6. Neutral is found by star connection only
  • 7. In star connection :
  • Line voltage =1.732*phase voltage
  • And line current = phase current
  • 8. Delta connection :
  • Line voltage = phase voltage
  • And line current = 1.732*phase current
  • 9. Star connection used for reducing insulating material and for neutral
  • 10. Colour code method used for resistor & capacitor
  • 11. Carbon is semiconductor material
  • 12. Diamond is the best insulator.
  • 13. Silver is the best conductor ( platinum also.. But not at normal temperature)

Power System

  • 1. Generation voltage =11kv
  • 2. Railway voltage =25k
  • 3. Low voltage =240v & 415volts
  • 4. High voltage = 11 & 33kv
  • 5. Extra high voltage = 66, 132, 220 & 400kv
  • 6. Ultra-high voltage = above 765kv
  • 7. ACSR conductor used to reduce skin effect
  • 8. Hollow and bundle conductor used to reduce corona effect
  • 9. To reduce the Ferranti effect… The reactor used in series
  • 10. Dielectric strength of air 30kv/cm(max)
  • And 21.1kv/cm(RMS)
  • 11. Air density factor 3.92b/(273+°c)

Electrical Machines Questions And Answers

  • 1. Cogging: when the starting of the induction motor fails called cogging. It’s due to Magnetic locking. To reduced it.
  • 2. Number of rotor slots not equal to stator slots and Rotor slots made skewed
  • 3. Crawling: when induction motor runs at 1/7 the of its rated speed called crawling. It’s due to 7 harmonic.
  • 4. To reduced armature reaction in Dc Machine compensating winding used. It is connected in series with armature winding and which is placed in pole shoes.
  • 5. Dummy coils used for Mechanical balance of rotor and it is not connected with armature winding and no current flows.
  • 6. Commutator in Dc generator acts like a rectifier( AC to dc)
  • Commutator in Dc motor acts like an inverter ( dc to ac)
  • 7. Color of silica gel in transformer breather :
  • In fresh condition = light pink
  • In bad condition = blue
  • 8. Primary voltage per turn = secondary voltage per turn

Synchronous Machine

  • 1. Rotor speed equal to the synchronous speed
  • 2. Two types of rotor :
  • (a).salient rotor = large dia & small length, suitable for low speed, Used in hydropower plant so call “hydro generator”
  • (b). Wound rotor = small dia & large length, suitable for high speed ( 3000 & 1500rpm) so-called “” turbogenerator”””, Used in steam, gas and nuclear power plant
  • 3. The normal speed of turbogenerator 3000rpm and normally number of poles is 2
  • 4. The maximum synchronous motor is salient pole motor
  • 5. Alternator and synchronous motor both are double excited Machine
  • 6. Synchronous motor is not self-starting
  • 7. For making synchronous motor self-starting, damper winding used
  • 8. Damper winding also used to reduce Hunting
  • 9. Vibration in the rotor by variable Mechanical input or variable load called Hunting
  • 10. damper winding placed in pole face of the salient pole
  • 11. The asynchronous condenser is an overexcited synchronous motor at No Load
  • 12. Synchronous motor is constant speed motor
  • 13. Mostly AC generator is a synchronous generator
  • 14. Slot harmonics produce in the alternator
  • 15. Full pitch winding ::: pitch factor is 1
  • 16. Short pitch winding ::: pitch factor is less than 1
  • 17. Dc shunt generator is used as exciter in the alternator

Electrical engineering interview question and answer on DC Machine

  • 1. Dc generator rating =KW
  • 2. Dc motor rating =hp
  • 3. Generally the number of poles 4
  • 4. Armature on rotor and field on stator
  • 5. For convert AC into dc armature made on the rotor
  • 6. Commutator works [in Dc generator AC into dc] and [in Dc into AC]
  • 7. Commutator made by hard drown copper
  • 8. Carbon brush
  • 9. In large rating dc generator brush made by copper
  • 10. Infield winding =dc supply
  • 11. In armature winding = AC current
  • 12. Dc series generator used in Dc transmission line as a booster
  • 13. Dc shunt generator =battery charger and exciter in the alternator
  • 14. Dc differential generator = welding
  • 15. Dc cumulative generator = Electro patting
  • 16. Dc series motor = traction, lift, crane
  • 17. Dc shunt motor = boring Machine, drill m/c
  • 18. Dc cumulative motor = coal cutting m/c
  • 19. Dc series motor highest starting torque
  • 20. Dc shunt motor is constant speed motor
  • 21. Dc shunt generator has a constant terminal voltage
  • 22. Dc shunt generator is suitable for parallel operation because it dropping characteristics
  • 23. Normal Efficiency range of dc m/c 80 to 85%

Electrical engineering interview question and answer on induction motor

  • 1. Always works on lagging power factor
  • 2. Air Gap length 0.4 to 4mm
  • 3. Air gap length try to keep minimum as possible for good power factor
  • 4. Synchronous speed = speed of stator flux
  • 5. Slip=(syn speed – rotor speed) / synchronous speed
  • 6. Slip rang 0.1 to 5% no load to full load respectively
  • 7. Slip at the start is 1 or 100%
  • 8. Rotor frequency = slip*supply frequency
  • 9. It is self-starting
  • 10. Power factor at No Load is 0.1 lagging and at full load 0.9 lagging
  • 11. Rotor speed < synchronous speed
  • 12. Slip is positive in IM
  • 13. Synchronous speed= (120*frequency) / poles
  • 14. Maximum synchronous speed 3000 RPM
  • 15. It is a single excited Machine
  • 16. No-load current 30 to 40% of full load current
  • 17. Rotor winding in star connection
  • 18. DOL starter use for up to 5hp
  • 19. Star delta starter for 5 to 20 hp
  • 20. Autotransformer starter for above 20hp
  • 21. Rotating resistance starter use only for sleeping induction motor

Electrical engineering interview question and answer on transformer

  • 1. Static device
  • 2. Higher Efficiency Machine
  • 3. Efficiency range 90 to 98%
  • 4. No-load current is 2-6% of full load current
  • 5. Buchholz relay is the gas-operated relay, used to protect the transformer from INTERNAL FAUT
  • 6. Open Circuit test=>> Iron losses
  • 7. Short Circuit test=>> copper loss at any load
  • 8. Tap changer used for change output voltage at the substation
  • 9. No Mechanical loss in transformer
  • 10. Transformer, alternator, induction motor and dc generator works on Electro Magnetic induction law
  • 11. LV winding wound near at core to save insulation cost
  • 12. Terry winding use to reduced 3rd harmonic
  • 13. Terry winding in delta connection
  • 14. The bushing is made by porcelain
  • 15. Scott connection used for convert 3 phase supply in 2 phase supply
  • 16. Delta star connection used for distribution system
  • 17. In open delta connection capacity is 58% of delta connection
  • 18. The power factor of the transformer and alternator depends on the load.

Important electrical engineering interview question and answer

  • 1. Low resistance R<1 ohm
  • 2. Medium resistance 1<R<100000 ohms
  • 3. High Resistance R>100000 ohms
  • 4. Earth resistance & Armature resistance are low resistance
  • 5. Insulation resistance is high resistance
  • 6. For low resistance Measurement, Kelvin double bridge method used
  • 7. For medium resistance Measurement wheat stone bridge used
  • 8. For high resistance Measurement, megger is used
  • 9. The highest speed of megger is 160 rpm
  • 10. Megger = ohm meter + handicraft permanent magnet dc generator
  • 11. Weine bridge used for frequency Measurement
  • 12. Schering bridge used for capacitance Measurement
  • 13. Heaviside bridge used for mutual Inductance
  • 14. Anderson bridge used for self Inductance of low-quality factory coils Q<1
  • 15. Hay bridge used for self Inductance of high-quality-factor coil s Q>10
  • 16. Maxwell Inductance capacitance bridge used for self Inductance of medium quality factor coils 1<Q<10.